Component Test Chamber

Components Test Chamber

Emissions:

1) Conducted RF on mains cable & other ports -Conducted transient emission power leads - LISN - ISO 7637 and CISPR 25

2) Radiated RF
    ALSE method - SAE J1113-41 / CISPR25

Immunity:

 1) Conducted RF on mains & other ports :-

Voltage drop simulation - ISO 7637-2 / SAE J1113/11
Power fail simulation - ISO 7637-2 / SAE J1113/11
Electrostatic Discharge (ESD) - ISO 10605 / SAE J1113/13
Direct injection - ISO 11452-7 / SAE J1113/3
Power leads (coupling mechanisms) - ISO 7637-3 / SAE J1113/12

2) Radiated RF :-

ALSE method - ISO 11452-2
TEM cell - ISO 11452-3 / SAE J1113/24
Whole vehicle Stripline - ISO 11452-8
Triplate antenna - SAE J1113/25
Bulk Current Injection (BCI) - ISO 11452-4 / SAE J1113/4
Magnetic immunity - Helmholtz coil - ISO 11452-8 / SAE J1113/22